GDP-C - Gas Permeability Tester

You can adjust the sample temperature within the range of -20°C and 80°C using an external thermostat.

The GDP-C software allows you to control the following processes:
  • Setting parameters for different test procedures
  • Viewing a graphical representation of the test procedures
  • Printing charts with the test graph
  • Saving your results in Microsoft Access databases
  • Retrieving and editing graphs and results from previous tests.
  • Saving edited graphs
  • Saving, retrieving and printing special test data (such as pre-conditioning).

Download Datasheet

Specifications  
Test method
Quantitative determination of the gas permeability of film materials using differential pressure (manometric method)
Test gas
All non-corrosive and non-flamable gases
Recommended gas flow
60 bis 100 cm³/min
Measuring Range
0.5 cm³/(m² d bar) bis 30,000 cm³/(m² d bar)
Resolution
0.1 cm³/(m² d bar)
Pressure sensor at the
piezoresistive element
permeation cell
measuring range 0 hPa to 1000 hPa (2 bar max.)
Tolerance (absolut)
< 0.3% of the final pressure (1000 hPa)
Resolution (internal 21 Bit)
< 0.05 hPa (with constant test temperature)
Data storage
up to 4096 test values (with dynamic time interval selection)
Perssure absorption gauge
piezoresistive element (0 hPa to 2000 hPa)
Tolerance
< 1% of the final pressure (1000 hPa)
Resolution (display)
0.1 hPa
Data storage
up to 512 test values (width dynamic time interval selection)
Sample temperature range
-20 °C to 80°C (with external thermostat)
Tolerance ( temperature sensors)
+/- 1.5°C
Resolution of the temperature display
0.1°C
Data storage
up to 512 test values (with dynamic time interval selection)
Sample temperature range
-20°C to 80°C (with external thermostat)
Dimensions
50 x 31 x 74 cm
Weight
20 kg
Storage temperature
0°C - 50°C
Working temperature
20°C - 26°C (to be constant during operation when testing films with a low GTR)
Relative humidity
max. 80%, non-condensing
Electrical connection GDPC
230 V / 50 - 60Hz, power consumption ca. 50 W, approx.
Electrical connection PC
230 V / 50 - 60Hz, power consumption ca. 50 W, approx.
Electrical connection monitor
230 V / 50 - 60Hz, power consumption ca. 150 W, approx.
Electrical connection(Thermostat) 230 V / 50 - 60Hz, power consumption ca. 2300 W, approx.
Standard
ISO / DIS 15 105 1
ASTM D1434 82 (M)

Accessories

Required Accessories
  • Vacuum Pump
Optional Accessories
Laboratory requirements
  • Mains Connection
  • Test Gas, 1 to 3 bar connection (such as O2)
  • Vacuum Connector
Expendables and recommended spares
  • High-Vacuum Grease
  • Petroleum Ether (cleaning agent for films and the film support)
  • Test Gas
  • Sealing Ring